Waste-heat recovery of turbine condenser water Method
Annotation:

One of the directions of energy saving is the application of heat pumps by means of which it is possible to use low-potential, usually waste heat. The question of the possibility of using heat pumps in thermal power plants is considered in the present article. Also a diagram of possible use in thermal power stations of low-grade waste heat with heat pump installation is presented in the article.

Author: А.P. Plevako
Year of release: 2015
Number of the journal: 2(58)

Possibility of using of thermal pumps at thermal power plants and heat boiler stations
Annotation:

Different diagrams of thermal pumps operation at thermal power plants are considered in the article. Thus, installation diagrams are considered for thermal pump based on the use of low -grade heat of turbo-unit lubricating system oil and blow-down water of a steam generator.

Author: А.P. Plevako
Year of release: 2019
Number of the journal: 2(74)

Methods for reducing nitrogen oxide emissions in steam generators of thermal power plants
Annotation:

One of the agent modern tasks is to ensure the cleanliness of the air basin. To ensure this, it is necessary to clean the combustion products of the fuel removed from the boilers after their cooling into the atmosphere from harmful substances, including nitrogen oxide.

Author: А.P. Plevako
Year of release:
Number of the journal:

The use of a heat pump at an industrial enterprise in the region
Annotation:

Main problem: The use of waste heat is most often solved by installing heat exchangers, but this is not effective when the temperature of this heat does not exceed 10-15 0 C, in which case this heat can be used using a heat pump. Where can I get this heat? Almost any enterprise needs cooling of any equipment elements or substances – working fluids; the heat received from them can be sent to a heat pump and used here at the enterprise. Purpose: Consideration of the possibility of using the heat of cooling water from the pump CNS 60-165 and the proposal of a new scheme with the installation of a heat pump that uses this heat. Methods: This is achieved due to the fact that it is proposed not to discard the heat, but after its use in the heat pump evaporator, transfer it to the heated medium - water, which is then sent to the shower cabins of the enterprise. Since the showers are located in the same room, the cost of transporting heat and losses will be minimal. Methods: In the course of the research, the possibility of using the waste heat of an industrial enterprise for using it here at the enterprise for the purposes of hot water supply was considered. For these purposes, it is proposed to install a heat pump, thanks to which the thermal potential increases, which makes it possible to fully use the received heat. Results and their significance: As the experience of foreign countries has shown, heat pumps can be widely used in many industrial enterprises, and in conditions of increased competitiveness, in order to reduce energy costs and the cost of manufactured products, install heat pumps to utilize excess heat, for example, process water, which is available in many production allows you to have a significant economic effect.

Year of release: 2022
Number of the journal: 2(86)

Energy savings through the use of refractory masonry with a lower thermal conductivity
Annotation:

Main problem: recently, much attention has been paid to energy saving in production, especially when it comes to industrial units that burn fuel. There are several ways to maximize the use of the heat released during the combustion process, for example, to reduce the temperature of the flue gases at the outlet of the unit, by maximizing its use, both in the technological process itself and by installing additional heat-receiving units, for example, air heaters or other heaters. Another way to save money is to reduce heat losses through the lining of these high-temperature units. Metallurgical units that consume a large amount of energy and fuel require an analysis of their consumption, and ways to save their consumption based on the results of the analysis. Purpose: this article considers the possibility of replacing the existing inner insulation layer of the second and third sections of a high-temperature unit - a metallurgical furnace, with a new one with better technical and economic indicators. Methods: the possibility of replacing the existing inner insulation layer of the second and third sections of the high-temperature unit with a new one, with the best technical and economic indicators, was considered. The calculation of heat losses by thermal conductivity through the side surfaces and the roof with new insulation was performed, and the economic efficiency of the proposed solution was proved. Results and their significance: replacing the existing inner layer of insulation - refractory concrete PHLOCAST M30 (thermal conductivity coefficient from 1,4 to 1,45) with the proposed CERALIT GUN HK 70070 (thermal conductivity coefficient from 1,03 to 1,12) will reduce heat loss to the environment, and thus to reduce fuel consumption for the furnace.

Author: А.P. Plevako
Year of release: 2022
Number of the journal: 4(88)